= Infrastructure/SOP/Raid Mismatch Count
|
||
|
|
||
|
What to do when a raid device has a mismatch count
|
||
|
|
||
|
== Contents
|
||
|
|
||
|
[arabic]
|
||
|
. Contact Information
|
||
|
. Description
|
||
|
. Correction
|
||
|
|
||
|
____
|
||
|
[arabic]
|
||
|
. Step 1
|
||
|
. Step 2
|
||
|
____
|
||
|
|
||
|
== Contact Information
|
||
|
|
||
|
Owner::
|
||
|
Fedora Infrastructure Team
|
||
|
Contact::
|
||
|
#fedora-admin, sysadmin-main
|
||
|
Location::
|
||
|
All
|
||
|
Servers::
|
||
|
Physical hosts
|
||
|
Purpose::
|
||
|
Provides database connection to many of our apps.
|
||
|
|
||
|
== Description
|
||
|
|
||
|
In some situations a raid device may indicate there is a count mismatch
|
||
|
as listed in:
|
||
|
|
||
|
....
|
||
|
/sys/block/mdX/md/mismatch_cnt
|
||
|
....
|
||
|
|
||
|
Anything other than 0 is considered not good. Though if the number is
|
||
|
low it's probably nothing to worry about. To correct this situation try
|
||
|
the directions below.
|
||
|
|
||
|
== Correction
|
||
|
|
||
|
More than anything these steps are to A) Verify there is no problem and
|
||
|
B) make the error go away. If step 1 and step 2 don't correct the
|
||
|
problems, PROCEED WITH CAUTION. The steps below, however, should be
|
||
|
relatively safe.
|
||
|
|
||
|
Issue a repair (replace mdX with the questionable raid device):
|
||
|
|
||
|
....
|
||
|
echo repair > /sys/block/mdX/md/sync_action
|
||
|
....
|
||
|
|
||
|
Depending on the size of the array and disk speed this can take a while.
|
||
|
Watch the progress with:
|
||
|
|
||
|
....
|
||
|
cat /proc/mdstat
|
||
|
....
|
||
|
|
||
|
Issue a check. It's this check that will reset the mismatch count if
|
||
|
there are no problems. Again replace mdX with your actual raid device.:
|
||
|
|
||
|
....
|
||
|
echo check > /sys/block/mdX/md/sync_action
|
||
|
....
|
||
|
|
||
|
Just as before, you can watch the progress with:
|
||
|
|
||
|
....
|
||
|
cat /proc/mdstat
|
||
|
....
|